Analisis Kompensasi Daya Reaktif terhadap Faktor Daya Motor Induksi Menggunakan Bank Kapasitor

Authors

  • Yosar Leman Politeknik Manufaktur Negeri Bangka Belitung
  • Sasha Avrilia Politeknik Manufaktur Negeri Bangka Belitung
  • Surojo Surojo Politeknik Manufaktur Negeri Bangka Belitung

DOI:

https://doi.org/10.33504/jitt.v4i2.467

Keywords:

Induction motors, Capacitors bank, Reactive power, Power factor, Capacitive compensation

Abstract

Induction motors are the most widely used electrical machines in industry and are classified as inductive loads that absorb significant reactive power, resulting in a low power factor. A low power factor increases line current, causes greater distribution losses, and may incur penalty charges from utility companies. This study experimentally analyzes the effect of a switchable capacitor bank on the power factor and line current of a three-phase slip-ring induction motor under three loading conditions (M = 1.6 Nm, 1.8 Nm, and 2 Nm) at a supply voltage of 380 V / 50 Hz. Eight capacitor bank switching levels ranging from 0 to 1,350 VAR were tested. The results show that the power factor improved significantly from 0.23–0.28 (no compensation) to 0.53–0.55 at the optimal level (1+2+3+4), while the line current decreased by up to 53% from 1.57–1.72 A to 0.73–0.82 A. The motor current remained unaffected by compensation, confirming that capacitive compensation only reduces reactive current on the supply side. Over-compensation was also observed when excessive capacitance was applied, causing the power factor to deteriorate. These findings confirm that proper capacitor bank sizing is critical and must match the reactive power demand at each load condition.

Downloads

Download data is not yet available.

References

M. F. Baskoro, E. Zondra, and M. P. Halilintar, “Analisis Faktor Daya Motor Induksi Tiga Phasa Dengan MetodeMeasured Current Only (Mco),” J. Tek., vol. 18, no. 1, pp. 22–31, 2024, [Online]. Available: https://doi.org/10.31849/teknik.v17i1

M. Ayaz, S. M. H. Rizvi, and M. Akbar, “Dynamic Power Factor Correction in Industrial Systems: An Automated Capacitor Bank Control Approach,” in 2023 2nd International Conference on Emerging Trends in Electrical, Control, and Telecommunication Engineering, ETECTE 2023 - Proceedings, 2023. doi: 10.1109/ETECTE59617.2023.10396685.

D. Lorenzo, Power Factor Improvement DL GTU104.1. Rozzano, Italy: De Lorenzo S.P.A., 2011.

B. Ferdiansah, A. Margiantono, and F. Ahmad, “Analisis Pengaruh Kapasitor Bank Terhadap Nilai Faktor Daya Dan Nilai Jatuh Tegangan,” Jambura J. Electr. Electron. Eng., vol. 5, no. 2, pp. 234–241, 2023, doi: 10.37905/jjeee.v5i2.20893.

S. HS, J. Napitupulu, J. Sinaga, and B. Sitorus, “Studi Kompensasi Daya Reaktif Terhadap Kenaikan Faktor Daya,” J. Teknol. ENERGI UDA, vol. 11, no. 1, pp. 11–20, 2022.

M. D. Prasetyo, S. I. Haryudo, Joko, and A. I. Agung, “Analisis Pemasangan Kapasitor Bank Terhadap Perubahan Nilai Faktor Daya Dan Jatuh Tegangan Pada Unit Power Plant Di Pusat Pengembangan Sumber Daya Manusia Minyak Dan Gas Bumi Cepu,” J. Tek. Elektro, vol. 11, no. 02, pp. 208–217, 2022.

D. A. Basudewa, W. Aribowo, M. Widyartono, and A. C. Hermawan, “Analisa Penggunaan Kapasitor Bank terhadap Faktor Daya Pada Gedung IDB Laboratory UNESA,” J. Tek. Elektro, vol. 09, no. 03, pp. 697–707, 2020.

R. A. Sinaga, H. Eteruddin, and A. Tanjung, “PENGARUH KAPASITOR TERHADAP FAKTOR DAYA MOTOR INDUKSI TIGA PHASA DI PT. MALINDO KARYA LESTARI,” J. Tek., vol. 15, no. 2, pp. 85–93, 2021.

Fatoni and O. Supriadi, “Efek Pemasangan Kapasitor terhadap Motor Induksi Tiga Fasa Tak Berbeban,” Epic J. Electr. Power Instrum. Control, vol. 5, no. 1, p. 99, 2022, doi: 10.32493/epic.v5i1.20555.

A. D. Lestari, Sunarto, and T. Tohir, “Analisis Pengaruh Variasi Nilai Kapasitor Bank terhadap Kinerja Motor Induksi Tiga Fasa Menggunakan ETAP,” in Prosiding Industrial Research Workshop and National Seminar, 2022, pp. 13–14. [Online]. Available: https://jurnal.polban.ac.id/proceeding/article/view/4284

E. Zondra and Arlenny, “Analisis Perbaikan Faktor Daya Motor Induksi Tiga Phasa Di Laboratorium Teknik Elektro Universitas Lancang Kuning,” J. Sains, Teknol. dan Ind., vol. 12, no. 2, pp. 232–241, 2015, [Online]. Available: http://ejournal.uin-suska.ac.id/index.php/sitekin

Downloads